RGF Series
Product Description
RGF series of absorbing materials, absorbing film made of high-permeability metal powder materials, with the characteristics of light, thin and flexible, used in electromagnetic compatibility/interference field, good material for RFI
1. The noise is converted into heat.
2. Broadband (10MHz~10GHz).
3. Highly insulated.
4. Both heat dissipation efficiency
Under normal conditions, our company provides a flexible flat film with length and width dimensions of 300mm x 300 mm (±10mm) and thickness range of 0.2mm~0.5mm for each frequency band, and can be cut to various length and width dimensions and Back double-sided tape design.
Applications
1. Handling of countermeasures against low-frequency electromagnetic interference (EMI)
2. Radar cross-sectional area (RCS) reduction. Radar phantom elimination. Antenna waveform adjustment
3. Reception of attenuated radar waves
4. High frequency circuit noise waveform adjustment
5. Prevention of radiated interference from electronic equipment
6. Various microwave equipment, microwave appliances
7. Electromagnetic wave leakage prevention of equipment
8. Remove unnecessary electronic interference
10. Desktop, nb, tablet, mobile phone and card reader
11. Unlimited sharing device, nuclear magnetic equipment and instruments
Product specifications
Product specifications
此產品委託中山台灣中山科學研究院測試
Product test method
Measurement method
According to the microwave anti-wave reflection attenuation and measurement method customized by our laboratory, this method refers to the method in the appendix [1] of the US military regulation MIL-A-17161D* (the measurement method is not the direct transmission of the signal and the direct absorption contact)
Measurement range 3~18GHz reflection attenuation characteristics (expressed by db loss value)
Generally speaking, -3db means 50% absorption, -6db means 75% absorption, -10db means 90% absorption, -20db means 99% absorption.
Measuring Instruments
HP8500B Vector Network Analyzer
Measurement unit
The product of the microwave reflection attenuation measurement report of the Microwave Measurement Laboratory of the Institute of Chemistry, Zhongshan Academy of Sciences, Taiwan